An Attempt on Methemoglobinemia: It’s Treatment and Relationship between Treatment and Cerebral Oximeter Value: Case Presentation

Şeker, İlknur S. and Özlü, Onur and Demiraran, Yavuz and Sezen, Gülbin and Boran, Ertay (2015) An Attempt on Methemoglobinemia: It’s Treatment and Relationship between Treatment and Cerebral Oximeter Value: Case Presentation. International Journal of Clinical Medicine, 06 (12). pp. 954-960. ISSN 2158-284X

[thumbnail of IJCM_2015122915011131.pdf] Text
IJCM_2015122915011131.pdf - Published Version

Download (576kB)

Abstract

Background: Our paper aimed to investigate whether there was a correlation among the pulse oximetry, cerebral oximetry (CO) and MetHb (methemoglobin) values of a patient with congenital methemoglobinemia who underwent a laparoscopic cholecystectomy operation. Case: The 35-year-old male patient with a weight of 70 kg, body massindex (BMI) of 21, American Society of Anesthesia status-2(ASA-2) category who was planned for laparoscopic cholecystectomy operation was identified to have been diagnosed with congenital methemoglobinemia as per his medical history was methemoglobin levels ranged between 12% and 20% according to the periodical measurements taken for the past 3 years. The patient received standard monitoring during anesthesia and device monitoring with a cerebral oximeter (Invos 5100C somatic/cerebral oximeter, Covidien) and a CO-oximetry (Rad ?87 “Rainbow”, Masimo Inc., Irvine, CA) device to continuously follow up his MetHb values was also added. During the intra-operative follow-up, the patient’s methemoglobin level rose to 16%, his peripheral oxygen saturation levels decreased to 86% and his cerebral oximetry values were identified to have also decreased; therefore, methylene blue (MB) was intravenously administered to the patient. The patient continued to be followed up in the post-operative period and he did not develop any complications. Discussion: Appropriate treatment and monitoring enabled the prevention of potential complications. We believe that monitoring with NIRS and MASIMO CO-oximetry device will enable physicians to perform a safe follow-up and treatment in the intraoperative and postoperative follow-up of methemoglobinemia patients.

Item Type: Article
Subjects: Science Repository > Medical Science
Depositing User: Managing Editor
Date Deposited: 14 Feb 2023 05:02
Last Modified: 17 Apr 2024 13:25
URI: http://research.manuscritpub.com/id/eprint/1592

Actions (login required)

View Item
View Item