Numerical Study of the Air Conditioning of a Room by a Two-phase Thermosyphon Loop Using Meteorological Data from Mamou (Guinea)

Diallo, Abdoulaye and Chesneau, Xavier and Diaby, Idrissa and El-Maktoume, Djanfar (2021) Numerical Study of the Air Conditioning of a Room by a Two-phase Thermosyphon Loop Using Meteorological Data from Mamou (Guinea). Physical Science International Journal, 25 (11). pp. 1-20. ISSN 2348-0130

[thumbnail of 737-Article Text-1421-1-10-20220915.pdf] Text
737-Article Text-1421-1-10-20220915.pdf - Published Version

Download (690kB)

Abstract

This paper presents a numerical study of the air-conditioning of a room by a two-phase thermosyphon loop using meteorological data from the Mamou region (Guinea). The room is composed of a rectangular roof and a passenger compartment in the form of a parallelepiped. In addition, the air-conditioning unit that operates with methanol is composed of an evaporator, a condenser, a riser and a downcomer. The heat transfer modelling governing the habitat model and the air conditioning loop is based on the nodal method. The coupling of the system is done by convective transfer between the internal air of the habitat and the surface of the evaporator. The equations are solved by the implicit finite difference method. Thus, this resolution made it possible to determine the influence of the parameters on the model. This work presents results of the habitat with and without the air-conditioning loop for typical days in March of Mamou. These results show that the use of the air conditioning loop can contribute to lowering the internal air temperature. The value of the maximum temperature of the indoor air of the habitat with the air conditioner is about 299 K while that of the air without air conditioner is about 303 K. The variation of parameters such as temperature, wall thickness, incident solar flux, air exchange rate and evaporator surface has a significant impact on the operation of the air conditioner and on the temperature of the conditioned room. A low wall thickness or a high air exchange rate contributes to the temperature increase in the room. For a wall thickness of 10 cm, 15 cm or 40 cm, the air temperatures are 301.5 K, 297 K and 296.9 K respectively. However, for a habitat without an air conditioner the temperature is 303 K when the wall thickness is 15 cm.

Item Type: Article
Subjects: Science Repository > Physics and Astronomy
Depositing User: Managing Editor
Date Deposited: 24 Mar 2023 05:07
Last Modified: 20 Sep 2023 06:31
URI: http://research.manuscritpub.com/id/eprint/407